Reactor 2 H-30, H-40 and H-50
hydraulic spray foam equipment
For medium- and high-performance foam applications and for roofing applications – contributes up to 23.6 kg (52 lb) per minute
The future technology for spray foam insulation
The advantages of a hydraulic system:
- Reliability – robust, durable and durable spray systems
- Less downtime – longer intervals between required maintenance
- Increasing daily productivity – particularly high cycle rates possible
Graco’s Hydraulic Reactor line ensures higher yields and high-performance spraying. It is ideal for factory OEMs or applicators that need to handle high volumes.
The autonomous Reactor 2 models are available as H-30, H-40 and H-50.
Easily accessible, practically placed electronics
Advanced control technology
- Tracks, monitors and saves project data
- The data can be downloaded to a USB stick and saved
- Storage of up to 24 chemical formulations
- Cylinder level indicator
Graco InSite remote data transmission technology
- FREE 6-month trial
- Transfers real-time operational activities to your smartphone, tablet or computer
- Included with Elite models
Quick and easy troubleshooting thanks to QR code links
- Leads to less downtime
Sacrificial surge protection
- Protects your electronics from excessive voltage surges
3 years warranty
- Covers the user display and the control modules
- One of the best in the industry
Specifications
Reactor 2 Hydraulic Proportioning System | |
Maximum Fluid Working Pressure for Bare Proportioners | |
Models H-30, H-40, and H-50 |
13.8 MPa, 138 bar
|
Minimum Fluid Working Pressure for Bare Proportioners | |
H-30 |
4.8 MPa, 48 bar
|
H-40, H-50 |
4.1 MPa, 41 bar
|
Fluid: Oil Pressure Ratio | |
Model H-40 |
1.91: 1
|
Models H-30 and H-50 |
1.64: 1
|
Fluid inlets | |
Component A (ISO) |
3/4 npt (f), 2.07 MPa, 20.7 bar maximum
|
Component B (RES) |
3/4 npt (f), 2.07 MPa, 20.7 bar maximum
|
Fluid outlets | |
Component A (ISO) |
# 8 1/2 in. JIC, with # 5 5/16 in. JIC adapter
|
Component B (RES) |
# 10 5/8 in. JIC, with # 6 3/8 in. JIC adapter
|
Fluid Circulation Ports | |
1/4 npsm (m) |
1.75 MPa, 17.5 bar
|
Maximum fluid temperature | |
88 ° C
|
|
Maximum output (10 weight oil at ambient temperature) | |
Model H-30 |
13 kg / min (60 Hz)
|
Model H-50 |
24 kg / min (60 Hz)
|
Model H-40 |
20 kg / min (60 Hz)
|
Output Per Cycle (A and B) | |
Model H-40 |
0.24 liters
|
Models H-30 and H-50 |
0.28 liters
|
Supply Voltage Tolerance | |
200-240V nominal, 1 phase |
195-264 VAC, 50/60 Hz
|
200-240V nominal, 3 phase |
195-264 VAC, 50/60 Hz
|
650-415V nominal, 3 phase |
338-457 VAC, 50/60 Hz
|
Amperage requirement (phase) | |
See the Models listing in the manual. | |
Heater Power (A and B heaters total) | |
See the Models listing in the manual. | |
Hydraulic Reservoir Capacity | |
13.6 liters
|
|
Recommended Hydraulic Fluid | |
Citgo, A / W Hydraulic Oil, ISO Grade 46
|
|
Sound Power, via ISO 9614-2 | |
90.2 dB (A)
|
|
Sound Pressure 1m From Equipment | |
82.6 dB (A)
|
|
Weight | |
H-40, H-50 |
272 kg
|
H-30, 10 kW |
247 kg
|
H-30, 15 kW |
252 kg
|
Wetted Parts | |
Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome, fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically resistant o-rings
|